TM 55-1520-240-23-8
10-78
INSTALL AFT TANK FUEL LINES AND ELECTRICAL WIRING
(Continued)
10-78
19.
Position electrical wiring (47) and clamp (78) on
tube mounting bracket (79). Install screw (80)
and washer (81).
20.
Position electrical wiring (47), wire clamp (82) on
tube clamp (83). Install screw (84), washer (85)
and nut (86).
21.
Remove four screws (87 and 88) and four
washers (89 and 90). Remove tags from wires
(91, 92, 93, and 94). Position electrical wire
terminals (95 and 96). Install four screws and
washers.
22.
Position four wires (91, 92, 93, and 94) in two
clamps (97). Tighten two screws (98).
23.
Position electrical wire (47) and wire clamp (99)
on pump mounting bracket (100). Install screw
(101) and washer (102).
INSPECT
FOLLOW-ON MAINTENANCE:
Install fuel level transmitter (Task 8-82).
Perform vent system pressure test (Task 10-117).
Install access door (Task 10-80).
Install fuel level shut-off valve (Task 10-82).
Test aft fuel tank (Task 10-32).
Perform vent system flow test (Task 10-118) on
affected tank.
Perform test of pressure refueling system (Task
10-119) and fuel feed system (Task 10-120).
Refuel helicopter (Task 1-51).
Bleed fuel system (Task 10-121).
Perform operational check of appropriate fuel system
(TM 55-1520-240-T).
Inspect for leaks (Task 10-4).
Close and lock aft intertank pod panel (Task 2-188).
END OF TASK
10-372