TM 55-1520-240-23-8
10-72.2
INSTALL LOW FUEL LEVEL SENSOR
(Continued)
10-72.2
3.
Connect wires (10, 11, 12, and 13) as follows:
a.
Connect yellow wire (10) to GND on sensor
(1) over slot (14). Use screw (15) and washer
(16).
b.
Connect red wire (11) to unmarked side of
sensor (1) over slot (14). Use screw (15) and
washer (16).
c.
Connect green wire (12) to GND on lower
sensor (9). Use screw (15) and washer (16).
d.
Connect black wire (13) to unmarked side of
lower sensor (9). Use screw (15) and washer
(16).
4.
Loosen two screws (17). Position wires (10 and
11) and (12 and 13) in clamps (18). Tighten
screws.
5.
Position plate (3) on bracket (19). Install plate
with four screws (20) and washers (21).
INSPECT
FOLLOW-ON MAINTENANCE:
Install forward fuel tank forward access door (Task
10-70) and raise and install forward fuel tank (Task
10-26), or install aft fuel tank forward access door
(Task 10-80).
Refuel helicopter (Task 1-51).
END OF TASK
10-357