TM 55-1520-240-23-8
10-70
INSTALL FORWARD FUEL TANK BOOST PUMP
(Continued)
10-70
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
NOTE
Procedure is same to install boost
pump in No. 1 or No. 2 fuel system
forward fuel tank. Installation of No. 1
(left) boost pump is shown here.
INSTALL BOOST PUMP
1.
Remove barrier paper and tape covering access
hole in tank (1). Clean tape residue from face of
tank. Use dry cleaning solvent (E162) and cloths
(E135). Wear goggles to protect eyes. Wear
gloves (E186).
Do not puncture or scratch lining
of fuel tank. If lining is broken, fuel
penetrates and activates self-sealing
layers. Activated layers swell and trap
fuel. Activated green spongy material
also contaminates fuel system. This
makes it necessary to replace fuel
tank and flush fuel system.
2.
Position boost pump (2) on pump bracket (3).
Install four bolts (4) and washers (5).
3.
Remove plug from hose (6) and cap from boost
pump (2). Connect hose to boost pump. Torque
how connector to 1125 inch-pounds.
4.
Connect electrical connector (7) to pump (2).
Lockwire connector to pump. Use lockwire
(E233).
INSPECT
10-345