TM 55-1520-240-23-8
10-68
INSTALL FORWARD TANK FUEL LINES AND ELECTRICAL WIRING
(Continued)
10-68
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
NOTE
Procedure is same to install No. 1 or
No. 2 forward tank lines and electrical
wiring. No. 1 (left) forward tank
installation is shown here.
1.
Remove barrier material and tape from hole in
tank (1). Clean tape residue from tank. Use dry
cleaning solvent (E162) and cloths (E135). Wear
goggles to protect eyes. Wear gloves (E186).
2.
Remove tags and position electrical wires (2).
3.
Position two electrical wire clamps (3) and two
tube clamps (4). Install two screws (5), washers
(6), and nuts (7).
4.
Position two tube clamps (8) and two electrical
wire clamps (9). Install two screws (10), washers
(11), and spacers (12).
5.
Remove tags and position two hoses (13).
Extreme care should be applied
during installation and inspection
to ensure that hose connectors are
properly installed. Serious damage
could occur to the helicopter if these
hose end fittings are not properly
torqued. (Refer to Task 1-13.)
6.
Connect two hoses connectors (14).
7.
Position two electrical clamps (15) on two hose
clamps (16). Install two screws (17), washers
(18) and nuts (19).
10-338