TM 55-1520-240-23-810-56.1INSTALL MAIN TANK (NO. 1 SYSTEM) FUEL LEVEL SHUTOFF VALVE(Continued)10-56.19.Position manifold (18). Install eight bolts (22),washers (23), and nuts (24).10.Remove plug from hose (25). Install conical seal(25.1). Install hose on manifold (18).11.Position hose clamp (26). Install bolt (27), twowashers (28), and nut (29).12.Position gasket (30).NOTETube (17) is not symmetrical. Makesure that the upper nut on the landinggear mount remains accessible wheninstalling the tube.13.Maneuver tube (17), fitting (31), and elbow (16)into position on manifold (18) and fittings (19).14.Install four bolts (32), washers (33), and nuts(34).Do not use strap wrench orover-tighten ring nuts. Failure of thebreakaway fittings may occur.15.Hand tighten four ring nuts (35) and lockwire.Use lockwire (E231).10-289