TM 55-1520-240-23-8
10-56
INSTALL MAIN TANK (NO. 1 SYSTEM) FUEL LEVEL SHUTOFF VALVE
(Continued)
10-56
1.
Position tube (1) on valve (2). Install four bolts (3)
washers (4) and nuts (5).
2.
Install packing (6) on breakaway fitting (7).
Position fitting on valve (2). Install four bolts (8)
and washers (9).
3.
Install packing (10) on flange of valve (2).
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
4.
Remove barrier material and tape from hole in
tank (11). Clean tape residue from tank. Use dry
cleaning solvent (E162) and cloths (E135). Wear
goggles to protect eyes. Wear gloves (E186).
5.
Pull two hoses (12) through hole in tank (11) to
outside of tank. Maneuver valve (2) into position
next to hole in tank (11). Connect two hoses
(12) to valve.
6.
Position valve (2) against face of tank. Install 10
bolts (13) and washers (14).