TM 55-1520-240-23-8
10-55.1
REMOVE MAIN TANK (NO. 1 SYSTEM) FUEL LEVEL SHUTOFF VALVE
(Continued)
10-55.1
10.
Remove two gaskets (23). Plug holes in four
fittings (24).
11.
Remove four packings (25) from elbow (4), tube
(8), and manifold (19).
10-275