TM 55-1520-240-23-7
9-131
INSTALL MASTER CAUTION PANEL
(Continued)
9-131
1.
Connect plug (1) to receptacle (2).
2.
Connect plug (3) to receptacle (4).
3.
Position panel (5) to center instrument panel.
4.
Tighten four fasteners (6).
INSPECT
FOLLOW-ON MAINTENANCE:
Install NVG Filter (With 17 ) (Task 9-125.3).
Perform operational check (TM 55-1520-240-T).
END OF TASK
9-530