TM 55-1520-240-23-7
9-130.1
TEST MASTER CAUTION PANEL (AVIM)
(Continued)
9-130.1
17.
Set test switch (43) to BRT. BRT indicator lamp
(47) shall come on. All capsules (48, 50 through
87) shall go bright.
18.
Slowly reduce dc supply (45) voltage to 18 vdc.
All capsules shall light dimmer as voltage is
reduced to 18 vdc.
19.
Press reset test switch (42). MCL lamp (49) shall
go out.
20.
Set test switch (41) to off. All capsules (48, 50
through 87) shall go out.
21.
Turn off power supply (45).
22.
Disconnect power supply (45) from test setup.
Disconnect caution panel (44) from test setup.
FOLLOW-ON MAINTENANCE:
None
END OF TASK