TM 55-1520-240-23-7
9-99.2
ASSEMBLE EMERGENCY POWER PANEL (AVIM)
(Continued)
9-99.2
4.
Install three foil markers (8) if needed.
5.
Install four turnlocks (9).
6.
Install one nut (10) on each indicator (11).
Position two indicators in panel (12) and install
washer (13) and one more nut (10) on each
indicator.
7.
Position two timers (14) in back of panel (12).
Install four screws (15) and nuts (16).
INSPECT
8.
Connect 10 wires (17) to 2 timers (14) and 2
indicators (11). Use solder (E360) and tubing
(E431) (TM 55-1500-323-25). Remove tags.
INSPECT
9.
Position panel (12) on housing (2). Install four
screws (18).
FOLLOW-ON MAINTENANCE:
Test emergency power panel (Task 9-99.3).
END OF TASK
9-368