TM 55-1520-240-23-7
9-99.2
ASSEMBLE EMERGENCY POWER PANEL (AVIM)
9-99.2
INITIAL SETUP
Applicable Configurations:
Without 74
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Soldering Iron
Gun-Type Heater
Materials:
Flux (E178)
Solder (E360)
Tubing, Heat Shrinkable (E431)
Personnel Required:
Aircraft Electrician
Inspector
References:
TM 55-1520-240-23P
TM 55-1500-323-25
1.
Position receptacle (1) in housing (2). Install two
posts (3).
2.
Position two relays (4) in housing (2). Install four
screws (5) and nuts (6).
3.
Connect eight wires (7) to relays (4). Use solder
(E360) and tubing (E431) (TM 55-1500-323-25).
Remove tags.
INSPECT
9-367