TM 55-1520-240-23-7
9-40
INSTALL MAIN CURRENT TRANSFORMER
(Continued)
9-40
NOTE
Procedure is same to install main
current transformers in either power
distribution panel (PDP). No. 1 left
PDP is shown here.
1.
Position main current transformer (1) in PDP (2).
Install four bolts (3), washers (4), and nuts (5).
2.
Pull wires (6) through holes in transformer (1).
3.
Remove tag and tape from three wires (6).
4.
Connect three wires (6) to generator bus
contactor (7). Install three washers (8) and nuts
(9).
5.
Connect electrical connector (10).
INSPECT
6.
Close panel (11). Secure six fasteners (12).
FOLLOW-ON MAINTENANCE:
Perform generator operational check (TM
55-1520-240-T).
END OF TASK