TM 55-1520-240-23-7
9-32
INSTALL MAIN AC GENERATOR
(Continued)
9-32
Oil (E254) is toxic. It can irritate skin
and cause burns. Avoid inhaling. Use
only with adequate ventilation. Avoid
contact with skin, eyes, or clothing.
In case of contact, immediately flush
skin or eyes with water for least 15
minutes. Get medical attention for
eyes.
NOTE
Procedures are same for No. 1 or No.
2 generator. No. 2 is shown.
1.
Install new packings (1) on oil transfer tubes (2).
Generator is heavy and can injure
personnel if it drops. Generator must
be held firmly and moved carefully to
prevent injury to personnel.
2.
Install new packings (3) on generator shaft (4)
and generator (5).
2.1.
Lubricate splines of shaft (4) with oil.
3.
Align generator (5) with studs (6) and transfer
tubes (2). If needed, turn adapter and plate
assembly (7) to align with splines of shaft (4).
4.
Position generator (5) on transmission (8).
5.
Install eight washers (9) and nuts (10). Torque
nuts to 120 inch-pounds.