TM 55-1520-240-23-7
8-97
REMOVE CLAMP MOUNTED INSTRUMENTS FROM MAINTENANCE PANEL
8-97
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Materials:
None
Personnel Required:
Aircraft Electrician
Equipment Condition:
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
Cargo Ramp Open and Level (Task 2-2)
NOTE
Procedure is the same for removing
hydraulic pressure, temperature
or reservoir level indicators from
maintenance panel. Removal of No.
1 Flight Control Hydraulic Pressure
indicator is shown here.
1.
Loosen round head clamp screw (1).
8-304