TM 55-1520-240-23-7
8-64
INSTALL FORWARD TRANSMISSION OIL PRESSURE TRANSDUCER
8-64
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Materials:
Cloth (E120)
Dry Cleaning Solvent (E162)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 55-1520-240-23P
TM 55-1500-323-25
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
1.
Clean bonding surfaces of transducer (1) and
mounting surface (2) (TM 55-1500-323-25). Use
dry cleaning solvent (E162), cloth (E120), and
gloves (E186).
2.
Position transducer (1). Install four bolts (3) and
washers (4).
3.
Connect hose (5) to transducer (1).
4.
Connect connector (6) to transducer (1).
INSPECT
FOLLOW-ON MAINTENANCE:
Close left forward work platform (Task 2-2).
Perform operational check (TM 55-1520-240-T).
END OF TASK
8-179