TM 55-1520-240-23-7
8-26.2
REPAIR PITOT-STATIC AND SIDESLIP TUBING
(Continued)
8-26.2
NOTE
During assembly of fittings, check
that the front and back ferrules
are correctly positioned in the
compression nuts and that ends of
tubing are clean and free of foreign
matter.
6.
Assemble a fitting (8) on each end of new tubing
(7). Use two compression nuts (9), four ferrules
(10 and 11), and a union (12).
7.
Position new tubing (7) and fittings (8) into cutout
section of installed tubing (3).
NOTE
Make sure that ends of tubing are
firmly seated against shoulder of
union.
8.
Tighten compression nuts (10) (Task 8-26.1).
INSPECT
FOLLOW-ON MAINTENANCE:
Leak check system (TM 55-1520-240-T).
END OF TASK