TM 55-1520-240-23-7
8-26.1
REPLACE PITOT STATIC AND SIDESLIP SWAGELOK FITTINGS AND
TUBING
(Continued)
8-26.1
DISCONNECT SWAGELOK CONNECTED PARTS
Do not pull connector or tubing
from nut. Ensure that ferrules
and compression nut stay with
either serrated tube connector or
non-corrugated tubing as applicable.
If ferrules slide from non-corrugated
tubing or serrated tube, install new
ferrules and thread compression nut
loosely into fitting body.
NOTE
This procedure is the same for
replacing swageloked connections
using either serrated tube hose
connections or non-corrugated tubing.
Non-corrugated tubing connections
are shown.
1.
Scribe index mark (1) on compression nut (2)
and fitting body (3).
2.
Hold fitting body (3) with a wrench. Using another
wrench, loosen compression nut (2).
3.
Remove compression nut (2) and tubing (4) from
fitting (3).
8-92