TM 55-1520-240-23-7
9-156
REPAIR HOIST OPERATORS PANEL
(Continued)
9-156
2.
Replace strap assembly as follows:
a.
Remove screw (5), washers (6), and nut (7)
from strap (8).
b.
Remove strap (8).
c.
Position new strap (8) on panel (9). Install
screw (5), washer (6), and nut (7).
INSPECT
3.
Replace decal as follows:
a.
Heat decal (10). Remove decal.
Methyl-ethyl-ketone (E244) is
flammable and toxic. It can irritate
skin and cause burns. Use only with
adequate ventilation, away from heat
or open flame. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
b.
Clean panel (9) decal surface with
methyl-ethyl-ketone (E244). Use cloths
(E120) to clean. Wear gloves (E186).
c.
Peel protective backing from new decal (10).
Install decal on panel (9).
INSPECT
FOLLOW-ON MAINTENANCE:
Install hoist operators panel (Task 9-157).
END OF TASK
9-631