TM 55-1520-240-23-6
7-210
REMOVE UTILITY RESERVOIR/COOLER TEMPERATURE SWITCH
(Continued)
7-210
1.
Loosen clamp (1) and disconnect duct (2) from
reservoir/cooler (3).
2.
Loosen clamp (4) and disconnect hose (5) from
elbow (6).
3.
Open valve (7) and drain fluid reservoir/cooler
(3). Use container and cloths (E135) for spilled
fluid. Wear gloves (E184.1).
4.
Connect hose (5) to elbow (6). Tighten clamp (4).
5.
Tag and disconnect cable plug (11.1). Use paper
tag (E264).
6.
Remove lockwire from switch (8), valve (9), and
bulb (10).
7.
Remove switch (8) and packing (11) from
reservoir/cooler (3). Use cloths (E135) for spilled
fluid. Wear gloves (E184.1).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-804