TM 55-1520-240-23-6
7-201
INSTALL UTILITY RETURN CONTROL MODULE FILTER CHECK VALVES
(Continued)
7-201
NOTE
Procedure is the same to install the
filter check valves. Filter check valve
out is shown here.
1.
Install two packings (1) and four retainers (2) on
valve (3).
2.
Install valve (3) in FLTR OUT CV port (4) of
module (5).
3.
Lockwire valve (4) to FILTER RV bolt (6). Use
lockwire (E231).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform operational check (TM 55-1 520-240-T).
Service utility hydraulic reservoir (Task 1-59 or 1-62).
Close cargo ramp (TM 55-1520-240-10).
END OF TASK
7-786