TM 55-1520-240-23-6
7-177
TEST ACCUMULATORS (60910, HP1323100, OR AD-B130-7-177 1D390) (AVIM)
7-177
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Reservoir (APP E-11)
Test Block (1323TF100 Hydra Power)
Hydraulic Test Stand
Nitrogen Supply
Soft Jawed Vise
Wood Dowel, 1/2 Inch X 9 Inches
Container, 2 Quart
Graduate, 5 cc and 100 cc (2)
Pressure Gage, 10 psi
Pressure Gage, 2000 psi
Pressure Gage, 5000 psi
Restrictor Valve (2)
Shutoff Valve (4)
Nipple, 1/4 Inch (2)
Tube, 1/4 Inch, 0 to 5000 psi
Tee, 1/4 Inch (5)
Stop Watch
Materials:
Cloths (E120)
Hydraulic Fluid (E199)
Gloves (E186)
Parts:
Packing
Retainers
Personnel Required:
Aircraft Pneudraulics Repairer
Inspector
References:
Appendix E
Equipment Condition:
Off Helicopter Task
Accumulator Installed In Crash Proof Box
Test Setup
General Safety Instructions:
Use suitable crash box to shield
personnel and equipment in case of
failure during test.
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Hydraulic fluid ejected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
7-734