TM 55-1520-240-23-6
7-175
ASSEMBLE ACCUMULATOR (HP1323100) (AVIM)
(Continued)
7-175
2.
Install piston (3) in housing (4), large end first.
Push to bottom of housing. Use rod (5).
3.
Install housing (4) in vise (6).
4.
Install two threadlocks (7) in retainer (8).
Threadlocks shall be trimmed flush with large
diameter of thread in retainer.
5.
Install packing (9) and two rings (10) on retainer
(8).
6.
Install retainer (8) in housing (4). Turn clockwise
until entire groove (11) can be seen.
7.
Install ring (12) in groove (11).
8.
Remove housing (4) from vise (6).
9.
If plates (13) are being replaced, transfer data to
plates. Install plates as follows:
Methyl-ethyl-ketone (E244) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention.
a.
Clean housing (4) and plates (13) with
methyl-ethyl-ketone (E244). Use cloth (E120)
and gloves (E186).
b.
Apply adhesive (E43) to all contact surfaces
between plate (13) and housing (4).
c.
Install plate (13) on housing (4).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform functional test (Task 7-177).
END OF TASK
7-727