REMOVE APU START MODULE ACCUMULATOR
(Continued)
7-172
1.
Remove lockwire from accumulator (1) and valve
and gage (2). Loosen nut (3).
2.
Completely loosen nut (3). Remove valve and
gage (2) and two packings (4) from accumulator
(1). Use gloves (E186).
Hold valve and gage to protect it when
removing accumulator. Otherwise,
damage can occur.
3.
Remove accumulator (1), packing (5), and two
retainers (6) from module (7). Use container and
cloths (E135) for spilled fluid. Use gloves (E186).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-718