TM 55-1520-240-23-67-168REMOVE PRESSURE CONTROL MODULE PRESSURE TRANSMITTER(Continued)7-1681.Disconnect connector (1) from transmitter (2).2.Remove transmitter (2) and packing (3) fromPRESS XMTR port (4). Use container and cloths(E135) for spilled fluid. Use gloves (E186).FOLLOW-ON MAINTENANCE:NoneEND OF TASK7-708