TM 55-1520-240-23-6
7-164
REMOVE PRESSURE CONTROL MODULE HIGH PRESSURE RELIEF VALVE
(Continued)
7-164
1.
Remove lockwire from valve (1).
2.
Remove valve (1), two retainers (2), and two
packings (3) from port (4). Use container and
cloths (E135) for spilled fluid. Use gloves (E186).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-696