TM 55-1520-240-23-6
7-8.1
SAMPLE HYDRAULIC FLUID FROM FLIGHT CONTROL AND UTILITY SYSTEM
RESERVOIR/COOLERS
7-8.1
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Sampling Bottle (3) (Refer to TB 43-0106)
Sampling Tube (3) (Refer to TB 43-0106)
Container, 2 Quart
Workstand
Materials:
Cloths (E135)
Gloves (E186)
Personnel Required:
Army Aviator (2)
Aircraft Pneudraulics Repairer
Inspector
References:
TB 43-0106
Equipment Condition:
Perform 15 Minute Ground Run (TM 55-1520-240-10)
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
Right and Left Pylon Access Panel Open (Task 2-2)
Right Forward Work Platform Open (Task 2-2)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Hydraulic fluid ejected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
7-56