TM 55-1520-240-23-67-8INSPECT FOR CONTAMINATION OF HYDRAULIC SYSTEMS(Continued)7-81.Check all six hydraulic filters (1). Inspect thatred indicator button (2) on bottom of each filterhas not extended.2.If button (2) is extended, apply hydraulic power tothat system.3.Depress button (2). If checking utility system,have pilot in cockpit motor either engine for 30seconds. If checking flight control system, havepilot in cockpit cycle control stick for 30 seconds.If button extends, filter element is clogged.4.Remove hydraulic power.5.Remove filter element on all contaminated filters(Tasks 7-33, 7-156, and 7-194 as required).6.Inspect removed element and determine sourceof contamination (FM 1-509).7.Install new filter element (Task 7-34, 7-157, or7-195 as required).FOLLOW-ON MAINTENANCE:As required.Close right forward walk platform (Task 2-2).Close pylon right access door (Task 2-2).END OF TASK7-55