TM 55-1520-240-23-6
7-51
INSTALL NO. 1 OR NO. 2 POWER CONTROL MODULE ACCUMULATOR
(Continued)
7-51
3.
Lockwire valve (1) to accumulator (3). Lockwire
accumulator to module (6). Use lockwire (E231).
4.
Install gage (7), 45º aft of outboard, and packing
(8) in fitting (9). Tighten nut (10).
INSPECT
FOLLOW-ON MAINTENANCE:
Service No. 1 or No. 2 flight control accumulator
(Task 1-63).
Perform operational check (TM 55-1520-240-T).
Close right forward work platform or install right pylon
access door (Task 2-2).
END OF TASK
7-256