TM 55-1520-240-23-6
7-31
REMOVE NO. 2 POWER CONTROL MODULE
(Continued)
7-31
1.
On right side of module (1), tag and disconnect
five tubes (2). Use cloths (E135) for spilled fluid.
Wear gloves (E186).
2.
Remove lockwire from two connectors (3). Tag
and disconnect two connectors from module (1).
3.
On left side of the module (1), tag and disconnect
five tubes (4). Use cloths (E135) for spilled fluid.
Wear gloves (E186).
4.
Remove lockwire from four connectors (5). Tag
and disconnect four connectors from module (1).
5.
Remove three bolts (6) and washers (7).
6.
Remove module (1).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-180