TM 55-1520-240-23-6
7-17
REMOVE FILL MODULE
7-17
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Materials:
Cloths (E120)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer
Equipment Condition:
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
Utility Hydraulic System Depressurized (Task 7-135.1)
Cargo Ramp Open and Level (TM 55-1520-240-T)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
1.
Rotate valve handle (1) counterclockwise to OFF
position.
2.
Remove screw (2) from two clamps (3).
3.
Disconnect three tubes (4) from unions (5). Use
cloths (E120) for spilled fluid. Use gloves (E186).
4.
Remove three unions (5) and packings (6) from
valve (7).
7-133