TM 55-1520-240-23-6
7-16.1
FLUSHING SERIOUSLY CONTAMINATED FLIGHT CONTROL OR UTILITY HYDRAULIC
SYSTEMS
7-16.1
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Container, 55 Gallon
Hydraulic Test Stand (2) (If Available) or AGPU Test
Stand
Filter Assembly Kit ADHT6814-M9716M (2)
Hoses
Workstand
Electrical Power Supply
Blade Tiedown Lines (3)
Container, 2 Quart (2)
Container, 2 Gallon (2)
Materials:
Cloths (E120)
Gloves (E186)
Parts:
Packings
Filters
References:
Task 1-24
Task 1-26
Task 1-59
Task 1-61
Task 1-60
Task 2-2
Task 2-3
Task 2-193
Task 2-208
TM 55-1730-229-12
TM 55-1520-240-T
Personnel Required:
Aircraft Pneudraulics Repairer (3)
Aircraft Electrician
Inspector
Equipment Condition:
Battery Connected (Task 1-39)
External Electrical Power On (Task 1-37)
Hydraulic Power Off
External Hydraulic Power Connected (Task 1-38)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Hydraulic fluid ejected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
Keep head, hands and other body
parts clear of moving flight controls.
Hydraulic forces are strong enough to
cause severe injury.
7-106