TM 55-1520-240-23-6
7-284
INSTALL CARGO DOOR PRESSURE ACTUATED VALVE
(Continued)
7-284
2.
Align two spacers (4) between valve (3) and
structure (5). Install two bolts (6), four washers
(7), and two nuts (8).
3.
Connect four hydraulic tubes (9) to valve (3).
Remove tags.
INSPECT
FOLLOW-ON MAINTENANCE:
Bleed the utility hydraulic system (Task 7-339).
Perform cargo ramp operational check (TM
55-1520-240-T).
Close ramp (TM 55-1520-240-T).
END OF TASK
7-1065