REPLACE FORWARD TRANSMISSION OIL COOLER BYPASS VALVE (Continued)
REMOVE FORWARD TRANSMISSION OIL COOLER
TM-55-1520-240-23-5 CH-47D Heilcopter Manual
Page Navigation
425
426
427
428
429
430
431
432
433
434
435
TM 55-1520-240-23-5
6-112.1
REPLACE FORWARD TRANSMISSION OIL COOLER BYPASS VALVE
(Continued)
6-112.1
INSTALL VALVE
6.
Coat packing (6) and thread of bypass valve (5)
with oil (E254). Install packing on valve.
7.
Install valve (5) in oil cooler (2).
Torque
valve to
80 inch-pounds
.
8.
Lockwire valve (5) to nipple (7). Use lockwire
(E231).
INSPECT
FOLLOW-ON MAINTENANCE:
Install forward transmission drip pan (Task 2-3).
Close left forward transmission fairing (Task 2-2).
Service forward transmission (Task 1-54).
END OF TASK
6-437