TM 55-1520-240-23-4
5-135
INSTALL PITCH LINK BOOT
5-135
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Materials:
Straps (E374) or Twine (E433)
Gloves (E186)
Cloth (E120)
Dry Cleaning Solvent (E162)
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 55-1520-240-23P
Task 5-99
General Safety Instructions:
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
NOTE
Procedure is same to install all
six pitch link boots. Installation
of pitch link boot on forward
weather-protective cover is shown
here.
1.
Clean contact surfaces of retaining ring (1) and
cover (2). Use cloth (E120) damp with solvent
(E162). Wear gloves (E186).
5-736