TM 55-1520-240-23-4
5-81.3.1
REPLACE LIGHTNING PROTECTION JUMPER STRIP
5-81.3.1
INITIAL SETUP
Applicable Configurations:
All
Tools:
Airframe Repairers Tool Kit, NSN 5180-00-323-4876
Heat Lamp
Vacuum Pump
Materials:
Abrasive Paper (E9)
Acetone (E20)
Cloth (E120)
Fiberglass Laminate (E168 or E168.1)
Scrim Cloth (E325)
Adhesive (E40, E41, E43 or E47.1)
Polyethylene Cup (E157)
Wood Spatula (E424)
Peel Ply (E270)
Teflon-Impregnated Fabric (E170)
Rubber Sheet (E318)
Fiberglass Cloth (E130)
Masking Tape (E388)
Sealing Tape (E396)
Teflon Tape (E399)
Polyvinyl Sheet (E284)
Temperature Indicating Strips (E413)
Gloves (E186)
Curing Agent (E158.1)
NOTE
Scrim cloth is not required if adhesive
(E41) is used. Adhesive (E41)
contains beads which prevent it from
being squeezed below the thickness
of the beads.
Parts:
Jumper Strip 114R1750-12
Doubler 114R1702-24
Personnel Required:
Aircraft Structural Repairer
Inspector
Equipment Condition:
Off Helicopter Task
5-478