TM 55-1520-240-23-4
5-79
INSTALL LIGHTNING PROTECTION JUMPER WIRE INSERT
(Continued)
5-79
Do not use more than compressed
air for cleaning purposes. Debris
propelled under pressure can
cause injury to eyes. Use source of
compressed air under 30 psi and
eye protection to prevent injury to
personnel.
Acetone (E20) can form toxic
vapors if exposed to flame. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
NOTE
Procedure is same to install any
lightning protection ground cable
insert. There are two ground cable
inserts in each rotary-wing blade.
1.
Clean insert hole (1). Use compressed air. Wipe
out hole. Use cloth (E120) damp with acetone
(E20). Wear goggles to protect eyes. Wear
gloves (E186).
5-450