TM 55-1520-240-23-4
5-23.1.2
INSPECT TIE-BAR ASSEMBLY
5-23.1.2
INITIAL SETUP
Applicable Configurations:
All
Tools:
Technical Inspectors Tool Kit, NSN 5180-00-323-5114
Magnifying Glass, 10X
Borescope
Materials:
Solvent (E162)
Cloths (E120)
Gloves (E186)
Personnel Required:
Aircraft Powertrain Repairer
Inspector
Equipment Condition:
Off Helicopter Task
General Safety Instructions:
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
5-123