TM 55-1520-240-23-3
4-155
INSTALL FADEC RELAY PANEL
4-155
INITIAL SETUP
Applicable Configurations:
With 74
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Materials:
None
Personnel Required:
Aircraft Electrician
Inspector
References:
TM 55-1520-240-23P
Equipment Condition:
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
1.
Position FADEC relay panel (10) on mounting
bracket (13).
2.
Install screws (11) and washers (12) on FADEC
relay panel (10).
3.
Position relays (6) on FADEC relay panel (10).
4.
Install screws (7), washers (8), and spacers (9)
on relays (6).
5.
Connect six connectors (5) to relays (6). Remove
tags.
6.
Position clamp (3) on wire bundle (4).
7.
Install screw (1) and washer (2) on clamp (3).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
4-511