TM 55-1520-240-23-34-41INSPECT CONNECTING LINK (DRAG STRUT) AND ENGINE MOUNT FITTINGS4-41INITIAL SETUPApplicable Configurations:Without 74Tools:Technical Inspection Tool Kit, NSN 5180-00-323-5114Dial Indicating Scale, 0 to 50 PoundsVernier CaliperMicrometerMaterials:Dry Cleaning Solvent (E162)Cloths (E135)Gloves (E136)Personnel Required:Medium Helicopter RepairerInspectorReferences:TM 1-1520-253-23Equipment Condition:Connecting Link Removed (Task 4-40)General Safety Instructions:Dry cleaning solvent (E162) isflammable and toxic. It can irritateskin and cause burns. Use only inwell-ventilated area, away from heatand open flame. In case of contact,immediately flush skin or eyes withwater for at least 15 minutes. Getmedical attention for eyes.4-214
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business