TM 55-1520-240-23-10
16-121
REPLACE EAPS SCAVENGE BLOWER DUCT
16-121
INITIAL SETUP
Applicable Configurations:
All
Tools:
Mechanics Tool Kit, NSN 5180-00-323-4692
Personnel Required:
Medium Helicopter Repairer
Inspector
Equipment Condition:
Remove EAPS (Task 16-109)
Remove Diffuser Duct (Task 16-118)
Remove Scavenge Blower Assembly (Task 16-120)
REMOVE
1.
Remove two cap screws (16), flat washers (15)
and saddle washers (17) from open end of
scavenge duct (8) where blower mounts.
2.
Remove eleven cap screws (19), eleven flat
washers (20), scavenge duct (8) and gasket from
EAPS.
INSTALL
3.
Install gasket (18) and scavenge duct (8) on
EAPS and attach with eleven cap screws (19)
and flat washers (20).
4.
Install two saddle washers (17), flat washers (15),
and cap screws (16) in open end of scavenge
duct (8).
INSPECT
FOLLOW-ON MAINTENANCE:
Install scavenge blower assembly (Task 16-120).
Install diffuser duct (Task 16-119).
Install EAPS (Task 16-110).
END OF TASK
16-382