TM 55-1520-240-23-10
16-59.30 STRAY VOLTAGE TEST PROCEDURES (Continued)
16-59.30
14.
If FAIL message followed by failed pin numbers
is displayed, stray voltage exists on the CMDS
dispense fire lines indicated and must be
corrected before payload modules can be
installed. Shut down aircraft power. Starting at
the dispenser pins, use multimeter to locate the
source of the stray voltage. If CMDS is not the
source of the stray voltage, aircraft wiring must
be checked to locate and repair the stray voltage
condition. After repairs, repeat this procedure
and retest until all lines pass.
15.
Set CDTS MODE switch to OFF.
16.
Set DCDU MODE switch to OFF.
17.
Repeat test for untested dispensers.
18.
Proceed with loading payload modules per Task
16-59.13.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
16-250.58
Change 1