TM 55-1520-240-23-10
16-54.2
INSTALL FLARE DISPENSER CONTROL PANEL
16-54.2
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Materials:
None
Personnel Required:
Aircraft Electrician
Inspector
References:
TM 55-1520-240-23P
Insure that wire bundle marked as
"mates with M/W 147A1" is connected
to flare dispenser control connector.
1.
Connect electrical connector (1) to receptacle (2)
on flare dispenser control panel (3). Remove tag.
2.
Position flare dispenser control panel (3) on
console (4).
3.
Tighten four fasteners (5).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform operational check (TM 55-1520-240-T).
END OF TASK