TM 55-1520-240-23-1016-16INSTALL FORWARD OR AFT CARGO HOOK SOLENOID COVER OR WIREHARNESS(Continued)16-16NOTEProcedure is same to install solenoidcover or wire harness on forward oraft hook.1.Install gasket (1) on wire harness (2).2.Feed wire harness (2) through hole (3) insolenoid cover (4).3.Install four screws (5) and washers (6). Torquescrews to 9 inch-pounds. Lockwire screws. Uselockwire (E227).Sealant (E340.1) can irritate skin andcause burns. Avoid contact with skin,eyes, or clothing. In case of contact,immediately flush skin or eyes withwater for at least 15 minutes. Getmedical attention for eyes.3.1.Apply sealant (E340.1) around harness (2) whereit comes through cover (4). Wear gloves (E186).4.Position gasket (7) on cargo hook (8).5.Remove any tags and connect eightharness wires (9) to modules (10). Useinsertion/extraction tool.6.Route wire harness (2) below modules (10) andtie harness to wires from solenoid protectionswitch (11). Tie harness and wires with strap(E377) (12).16-106