TM 55-1520-240-23-10
15-3
REMOVE AUXILIARY POWER UNIT (APU)
(Continued)
15-3
NOTE
Hoist operating instructions are
marked on hoist.
13.
Position lug (35) of hoist (36) in clevis (37) on
structure (38). Install bolt (39) and nut (40).
14.
Route cable (41) through tackle block (42). Hook
tackle block to fitting (43) on structure (38).
15.
Attach cable (41) to links (44) on APU (17) with
bolt (45) and nut (46).
Make sure slack is removed from
hoist cable. Otherwise, APU could
drop when it is disconnected causing
injury to personnel.
16.
Operate hoist (36) to remove slack from cable
(41).
15-11