TM 55-1520-240-23-10
15-3
REMOVE AUXILIARY POWER UNIT (APU)
(Continued)
15-3
NOTE
Ensure APU generator wires
are properly tagged as the APU
generator manufactures (Lucas and
Leland) have different wire terminal
attachment points.
1.
Loosen two fasteners (1) and remove terminal
cover (2). Tag and disconnect six wires (3) by
removing six nuts (4) and washers (5). Tape wire
ends. Use tape (E385).
2.
Loosen two fasteners (6) and remove terminal
cover (7). Tag and disconnect four wires (8) by
removing four nuts (9) and washers (10). Tape
wire ends. Use tape (E385).
3.
Loosen two fasteners (11) and remove terminal
cover (12). Tag and disconnect three wires (13)
by removing three nuts (14) and washers (15).
Tape wire ends. Use tape (E385).
4.
Tag and disconnect drain hose (16) at auxiliary
power unit (APU) (17). Use container and cloths
(E135) for spilled fuel. Plug hose and cap fitting
(18).
5.
Deleted.
6.
Tie motor-pump (21) out of way. Use twine
(E433).
15-9