TM 55-1520-240-23-10
13-66
INSTALL HEATER IGNITION UNIT
(Continued)
13-66
3.
Position ignition unit (6) in brackets (1 and 2) as
shown.
NOTE
Without 16 have switch (6.1). With
16 do not have switch (6.1).
4.
Install two screws (7) and washers (8).
5.
Connect shielded lead (9).
6.
Connect electrical connector (10).
7.
Lockwire connector (10). Use lockwire (E231).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform operational check (TM 55-1520-240-T).
Install heater compartment acoustic blanket (Task
2-210).
END OF TASK
13-181