TM 55-1520-240-23-10
13-21
INSTALL HEATER EXHAUST PIPE
(Continued)
13-21
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
9.
Clean joint between stack (1) and pipe (2). Use
dry cleaning solvent (E162) and cloths (E120).
Wear gloves.
10.
Apply a fillet (14) of sealant (E332.1) to the joint.
11.
Install exhaust shroud elbows (15) around pipe
(2).
12.
Lace wire shroud elbows (15) together. Use
lockwire (E233).
13.
Install clamp (16).
14.
Seal stack (1) to edge of skin. (Task 2-324).
INSPECT
FOLLOW-ON MAINTENANCE:
Install heater compartment acoustical blanket (Task
2-210).
END OF TASK