TM 55-1520-240-23-1
1-103
SERVICE HELICOPTER AFTER SHORT TERM STORAGE
1-103
INITIAL SETUP
Applicable Configurations:
All
Tools:
As Required
Materials:
Barrier Material (E81)
Cloth (E120)
Hydraulic Fluid (E197)
Cleaning Solvent (E161)
Gloves (E186)
Oil (E254)
Tape (E388)
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 11-1520-240-20
TM 11-6140-203-14-2
TM 55-1520-240-T
TM 55-2835-205-23
DA PAM 738-751
Task 1-26
Task 1-27
Task 1-29
Task 1-32
Task 1-37
Task 1-39
Task 1-51
Task 1-53
Task 1-54
Task 1-58
Task 1-59
Tasks 1-62 thru 1-68
Tasks 1-71 thru 1-73
Task 1-76
Task 1-77
Task 1-78
Task 1-83
Task 1-88
Task 1-90
Task 1-107
Task 5-4
Task 5-84
Task 5-92
Task 5-93
Task 5-96
Task 6-130
Task 6-131
Task 6-132
Task 6-155
Task 6-156
Task 6-180
Task 6-181
Task 6-209
Task 6-210
Task 6-211
Task 7-8
Task 9-27
Task 10-33
General Safety Instructions:
Dry cleaning solvent (E161) is
combustible and toxic. It can irritate
skin and cause burns. Use only with
adequate ventilation, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
Do not perform system or component
operational check until system
or component is depreserved
and serviced. Equipment can be
damaged.
AIRFRAME
1.
Prepare airframe for service as follows:
a.
Remove moorings and tiedowns (Tasks 1-26
and 1-27).
b.
Remove and stow protective covers (Task
1-32).
c.
Clean fuselage inside and outside surfaces
(Tasks 1-76, 1-77, and 1-83).
d.
Open cabin door.
e.
Open cockpit windows.
f.
Open ramp (TM 55-1520-240-T).
g.
Remove screening from fuselage, ramp and
pod drains.
h.
Close ramp and pod drain valves.
i.
Remove static ground wire (Task 1-29).
1-377