TM 55-1520-240-23-1
1-102
PREPARE HELICOPTER FOR SHORT TERM STORAGE
1-102
INITIAL SETUP
Applicable Configurations:
All
Tools:
As Required
Materials:
Tape (E388)
Oil (E254)
Lubricating Oil (E251)
Cloths (E120)
Dry Cleaning Solvent (E161)
Corrosion Preventive Compound (E153 or E154)
Barrier Material (E81)
Metal Conditioner and Rust Remover (E242
Hydraulic Fluid (E197)
Gloves (E186)
Corrosion Preventive Compound (E465)
Personnel Required:
Medium Helicopter Repairer (2)
Inspector
References:
DA PAM 738-751
TM 11-6140-203-15-2
TM 55-1500-333-24
TM 55-1520-240-10
TM 55-2835-205-23
TM 55-2840-254-23
Task 1-5
Task 1-26
Task 1-27
Task 1-29
Task 1-32
Tasks 1-37 thru 1-39
Tasks 1-53 thru 1-58
Task 1-59 or 1-62
Task 1-60
Task 1-61
Tasks 1-63 thru 1-70
Tasks 1-76 thru 1-78
Tasks 1-80 thru 1-84
Task 1-88
Task 1-90
Task 1-106
Task 5-2
Task 5-64
Task 5-65
Task 5-87
Task 5-91
Task 17-4
Equipment Condition:
As Required
General Safety Instructions:
Lubrication oil (E254) and hydraulic
fluid (E197) are toxic. They can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
1-371