TM 55-1520-240-23-1
1-51
SINGLE POINT REFUELING
(Continued)
1-51
33.
Install cap (12) on adapter (14).
If pressure is not relieved, fuel
may seep or spill when refueling is
completed.
34.
Relieve fuel pressure in the lines by evacuating
fuel as follows:
a.
Apply ac power to the helicopter (Task 1-37).
b.
Operate any of the main tank boost pumps
for about two minutes. Use switches (17).
c.
Remove ac power (Task 1-37).
FOLLOW-ON MAINTENANCE:
Close forward right landing gear access panel (Task
2-2).
END OF TASK
1-200